MIL-STD-1330D(SH) APPENDIX D
w/ Change 1
DATA SHEET 4. OSEE (SQM) Analysis of Cleaned Item.
Control Number:
Name and ID (e.g., badge):
Date:_
Description of item being cleaned:
Visual inspection of effluent or waste solvent:
Particulate:_ Turbidity or color:
Evaporating Dish:
Results from data sheet 3:
Clean Dish Acceptance Criteria:_ Dish 5 ppm Acceptance Criteria:
Cleaning Solvent:_ (HCFC-225G, HCFC-225M, HFE-7100 or CFC-113)
Gain Settings: Sensor:
Control Unit:_
Reading/Dose |
SQM Reading |
Cleaned Dish |
|
Reading #1 |
|
Reading #2 1/ |
|
Analysis of Effluent or Waste Solvent |
|
Dose #3 2/ |
|
NOTES: 1/ Reading #2 must be within 100 counts of Clean Dish Cleanliness Acceptance Criteria entered above from data sheet 3. 2/ (a) If dose #3 is less than the Clean Dish Acceptance Criteria plus 50 counts and greater than or equal to the Dish 5 ppm Acceptance Criteria, the results are acceptable and are reported as less than 5 ppm oil and grease. (b) If dose #3 is less than the Dish 5 ppm Acceptance Criteria, the results are not acceptable and the item requires recleaning. (c) If dose #3 is greater than or equal to the Clean Dish Acceptance Criteria plus 50 counts, the results are not acceptable and the item requires recleaning. |