MIL-STD-1330D(SH)
w/ Change 1
5.10.1.1 The component being removed and adjacent piping and equipment shall be externally cleaned with an aqueous cleaner or NAVSEA approved halogenated solvent1 to remove loose scale, dust, dirt, and other foreign material. Ultraviolet and white light inspections as specified in 5.13.1.2 and 5.13.1.3 shall indicate no visible contamination.
1For critical applications, NAVSEA approved halogenated solvents may be used for external cleaning with local engineering approval.
5.10.1.2 That portion of the system to be entered shall be isolated with appropriate boundary isolation valves and depressurized. Discharge of any fluid shall be in accordance with the appropriate safety precautions of NAVSEA S9086-SX-STM-010/CH-550.
5.10.1.3 Personnel clothing, including cleanroom gloves as specified in 5.1.6, Class B, paragraph (c), or equal shall be worn whenever handling the wetted surface of oxygen clean components. Oxygen clean component wetted surfaces touched with bare hands shall be considered contaminated and shall be cleaned as specified in 5.2 to re- establish oxygen cleanliness.
5.10.1.4 Systems containing oxygen at levels greater than 22 percent or hydrogen at levels greater than 3 percent shall be purged with helium or nitrogen to eliminate fire or explosion hazards using one of the following procedures:
a. Where the configuration allows a purge path, the affected can be purged with helium or nitrogen until the effluent purge gas measures not greater than 22 percent oxygen or 3 percent hydrogen. The measurement shall be taken using suitable colormetric gas detector tubes such as those manufactured by Draeger Manufacturing Company or a portable analyzer or other equivalent means.
b. Where the configuration does not allow a purge path such as a flask, or gas sampling equipment to measure oxygen or hydrogen is not available, verify the affected area is depressurized, then pressurize to about 100 lb/in2
with helium or nitrogen, and then depressurize the affected area. Repeat the cycle one additional time for oxygen or
oxygen enriched systems for a total of two pressurization-depressurization cycles. For hydrogen systems, the pressurization-depressurization cycle shall be performed two additional times for a total of three times. Sampling to measure oxygen or hydrogen concentration is not required.
5.10.1.5 Only certified oxygen clean items, including replacement pipe, components, and tools, shall be installed or come in contact with the wetted surface of an oxygen clean system or component. Oxygen clean items removed for transportation shall be immediately packaged as specified in 5.16. If cleanliness is lost because of torn packaging, maintenance, or repair, the effected item shall be cleaned as specified in 5.2 to re-establish oxygen cleanliness.
5.10.1.6 Socket and seal welding in accordance with NAVSEA S9074-AR-GIB-010/278, or equal, are considered clean processes that do not result in loss of oxygen cleanliness provided that a purge as specified in
5.10.2 is maintained. Any other welding or brazing processes result in a loss of oxygen cleanliness that requires recleaning as specified in 5.5 or 5.8.
5.10.1.7 Establish the containment or purge requirements as specified in Table IX. When a system is opened to remove an item, perform a visual inspection as specified in 5.13.1. Any visible contamination of the wetted surfaces shall be locally cleaned as specified in 5.12.4. Complete the necessary maintenance and repair. Prior to closing the system, repeat the visual inspection as specified in 5.13.1 for visual contamination. Any evidence of visible contamination may be an indication that loss of cleanliness has occurred and additional inspections as specified in
5.12 shall be accomplished.
5.10.1.8 If there is an unscheduled delay whatsoever, such as the wrong material, an incorrect part, or contamination, between the time that the system is opened and the time that the replacement component is installed, the open portions of the system shall be packaged as specified in 5.16.1.3. When the system is reopened, perform a visual inspection as specified in 5.13.1. Any evidence of visible contamination may be an indication that loss of cleanliness has occurred and additional inspections as specified in 5.12 may be required.
5.10.2 Purge. When the system is open, a slight positive purge of about 2 lb/in2 helium or nitrogen shall be maintained within the system to prevent possible entry of airborne contamination.
33
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business