MIL-STD-1330D(SH) APPENDIX A
w/ change 1
TABLE A-III. Plastic material compatibility.
PLASTIc; specification |
NOc 170 °F 1/ |
TSP 170 °F 1/ |
WATER 170 °F 1/ |
NID 1/ 2/ |
ABS, Acrylonitrile butadiene styrene; commercial |
c |
c |
c |
NH |
DELRIN, Acetal resin; ASTM D4181 |
c |
c |
c |
c |
EPOXY, Epoxy resin; commercial, unfilled |
I |
I |
I |
c |
HDPE, High density polyethylene; ASTM D1248 |
c |
c |
c |
c |
LEXAN, Polycarbonate resin; commercial |
c |
c |
c |
c |
LUcITE & PLEXIGLASS, Methyl-methacrylate; MIL-P-5425, finish A |
I |
1L |
1L |
c |
NYLON, Polyamide resin; ASTM D4066, nylon 6,6 |
1L |
1L |
1L |
1L |
PAI, Polyamide-imide (Torlon 4203L); commercial, injection molded |
12L |
12L |
c |
NH |
PEI, Polyetherimide (Ultem 1000); commercial, injection molded |
1L |
1L |
c |
c |
Polyurethane; commercial |
12L |
c |
I |
NH |
PP, Polypropylene; ASTM D4101, unfilled |
12L |
c |
c |
c |
PVc, Polyvinyl chloride; ASTM D1784, rigid |
c |
c |
c |
c |
PVc, Polyvinyl chloride; ASTM D2287, nonrigid |
12L |
c |
12L |
c |
SURLYN, Ionomer resin; commercial, No. 9650 |
NT |
I |
I |
c |
SURLYN, Ionomer resin; commercial, No. 9720 |
I |
c |
c |
c |
TEFLON FEP, Fluoethyl propylene; ASTM D2116 |
c |
c |
c |
c |
TEFLON TFE, Polytetrafluoro-ethylene; ASTM D1457 |
12L |
12L |
c |
c |
VESPEL-21, Polyamide resin + graphite; commercial |
1L |
1L |
NT |
c |
NOTES: 1/ "c" indicates that the material is compatible with the cleaning agent. "I" indicates that the material is not compatible with the cleaning agent. "1L" indicates that exposure of the material should be limited to 1 hour per cleaning. "12L" indicates that exposure of the material should be limited to 12 hours per cleaning. "c/D" indicates that the material is compatible with the cleaning agent, but the material surface was discolored during testing. Testing on a sample of the material may be necessary to determine if the discoloration is permissible. "NT" indicates that the material was not tested. 2/ compatibility of NID is based on test data and service history. "NH" indicates that there is no test data or history on the material compatibility. |