MIL-C-52705B
Critical
1. Holes in casting (see 3.3.3.1).
Major
101. Dimensions not as specified (see 3.1).
102. Material not as specified (see 3.3).
103. Materials are not resistant to corrosion or deterioration, or treated to be made resistant
to corrosion or deterioration for the applicable storage and operating environment as
specified (see 3.3.1).
104. Contractor does not have documentation available for identification of materials,
material finishes, or treatments (see 3.3.2).
105. Finish not as specified (see 3.4).
106. Corrugations not as specified (see 3.5).
107. Threads not as specified (see 3.6).
108. Incorrect or missing parts (see 3.7).
109. Identification marking missing, incomplete, or illegible (see 3.9).
110. Workmanship not as specified (see 3.10).
4.5.2 Test.
4.5.2.1 Hydrostatic test. Subject the complete coupling assembly to a hydrostatic pressure of
400 psig for not less than 30 seconds. Examine the coupling assembly for leakage, rupture, and
yielding. Leakage, rupture, or yielding shall constitute failure of this test.
4.5.2.2 Spectro-chemical analysis. Not less than a 2-ounce metal specimen shall be taken
from each lot of couplings for analysis in accordance with ASTM E 172. Failure to meet the
requirements of 3.3.4 shall constitute failure of this test.
4.6 Inspection of packaging. The preservation, packing and marking shall be examined and
tested in accordance with the quality assurance provisions of MIL-H-775.
5. PACKAGING
5.1 Preservation, packing and marking. The levels of preservation, packing and marking
shall be in accordance with MIL-H-775, or as specified by the contracting activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but
is not mandatory.)
6.1 Intended use. The couplings are intended for use in joining hose in steam systems, under
250 psig.