MIL-DTL-52618/7E
REQUIREMENTS:
The fittings shall be as specified on figure 1.
The design, dimensions, and tolerances of couplings and street elbows shall be in accordance with
ASME B16.14.
Intended use is with water, oil, or air 150 psi max. at 72°F.
Aluminum shall be in accordance with MIL-DTL-52618.
Configuration designators shall be in accordance with table I.
TABLE I. Configuration code letter for fittings.
Configuration code
Description
P
Solid pattern
Q
Cored pattern
R
Hollow cored pattern
S
Countersunk pattern
Size code numbers shall be in accordance with table II.
TABLE II. Size code numbers for fittings.
Nominal pipe size
Size code numbers
(inch)
01
1/8
02
1/4
03
3/8
04
1/2
05
3/4
06
1
07
1 - 1/4
08
1 - 1/2
09
2
10
2 - 1/2
11
3
12
3 - 1/2
13
4
Pipe threads shall be in accordance with MIL-DTL-52618.
Pipe thread direction code shall be in accordance with table III.
TABLE III. Thread direction code letter.
Thread direction code
Thread direction
letter
X
Right-hand
Y
Left-hand
Z
Right- and left-hand